Exova MeTech
  Text Only  |  Home  |  Accessibility  |  Sitemap  |  Change Text Size  Small TextMedium TextLarge Text  
   
This table contains the Main Menu navigation.
This table contains the main page content.

Calibration services

Exova METECH is an independent supplier performing metrological confirmation, calibration and repair of measuring instruments.

We handle most of the manufacturers on the market and perform calibration at any of our service centres or on site. As a supplier, we are certified according to ISO 9001:2000 and our accredited laboratories are accredited by Accreditation Bodies according to ISO/IEC 17025.

Our services are designed to help you as a customer to fulfil the requirements that have been put on maintenance and calibration of your measuring instruments. All the services provide metrological confirmation of the measuring instrument that fulfils the requirements in standards as ISO 9000 and ISO 10012.

Table containing information on Bodycote MeTech Calibration services

Calibration

When you need evidence that the measuring instrument comply with specification. This service fulfils the requirements in ISO 9000 and ISO10012.

Metrological confirmation by:

  • Calibration and test for compliance with the given specification
  • Adjustment when the measuring instrument does not comply with the specification, where possible
  • Calibration certificate stating compliance or non-compliance. Measurement results are only included at non-compliance or when adjustment is performed (1)
  • Records of the calibration certificate and measurement results are stored for 6 years
  • Sealing and labelling as "Calibrated"

Calibration + measurement results

When you need evidence that the measuring instrument comply with specification. This service fulfils the requirements in ISO 9000 and ISO10012.

Metrological confirmation by:

  • Calibration and test for compliance with the given specification
  • Adjustment when the measuring instrument does not comply with the specification, where possible
  • Calibration certificate including measurement results stating compliance or non-compliance. Measurement results are reported for each instrument point (1)
  • Records of the calibration certificate and measurement results are stored for 6 years
  • Sealing and labelling as "Calibrated"

Accredited Calibration

When you need measurement results and evidence that the measuring instrument comply with specification. This service gives and internationally recognized calibration and fulfils the requirements for calibration according to ISO/IEC 17025. e.g to fulfil the requirements in QS 9000 and ISO/TS 164949.

Metrological confirmation by:

  • Calibration at an accredited laboratory and test for compliance with the given specification 
  • Adjustment when the measuring instrument does not comply with the specification, where possible (2)
  • Calibration certificate issued by an accredited laboratory stating compliance or non-compliance. Measurement results are reported for each instrument point (1)
  • Records of the calibration certificate and measurement results are stored for 6 years
  • Sealing and labelling as "Calibrated"

The calibration usually covers the complete specified range, but can be customized to your needs (3). Measurement points are selected in accordance with the manufacturer’s performance test or equivalent.

The measurement procedures and the test equipment are selected to ensure traceability to national and international standards.

The uncertainty of measurement is accounted for when performing a compliance or non-compliance test. If the measuring instrument does not comply with the specification after adjustment or repair is needed, the customer is contacted before any further action.

(1) When adjustments are performed, measurement results are reported for the actual points.

(2) You can order not to perform any adjustments, e.g. for reference equipment where calibration history is important.The measuring instrument is then shipped, no matter if it comply with the specification or not.

(3) The complete specification refers to relevant parts of the specification.When performing accredited calibrations, where not all of the parameters are covered by the accreditation, the calibration will be complemented by non-accredited measurements to cover the complete specification.When the complete specification cannot be covered, the equipment is labeled ”Limited calibration”.


In this section:

Traceability
Diagram to show the traceability of the calibration services we provide to our customers

Definitions
Definitions according to International Vocabulary of Basic and General Terms in Metrology

On-Site Services
Many of the services performed by Exova METECH are carried out on site at customer’s facilities

Accredited Laboratories
Exova METECH's accredited laboratories provide a calibration service that gives an internationally recognised calibration that fulfils the requirements for calibration according to ISO/IEC 17025

Print this page. This will open a new browser window.PrintSend a link to this page via e-mail. This will open a new browser window.Email
This table contains contact details for this section.
Contact
Patrik Persson
Technical Director
Email:
Tel: +46 (0)768 664711
Lovisa Engström
Quality Director
Email:
Tel: +46 (0)13 181233
Layout spacer image.
This table contains the Featured Items
This table contains the footer menu.
Last updated:   | Legal | Help | Any problems?